Inombolo yemithombo:800G OSFP QSFP-DD SR8/DR8/FR8/LR8/ER8/ZR8
Ukubonisa umlingani
Amamojuli E-OSFP & QSFP-DD Transceiver Angu-800G
| Izithumeli Zokuxhumana Zokubona Ezihlukahlukene Ezisuka Kude Kuye Kude
Isibuyekezo Somkhiqizo
Ama-transceiver optical we-800G OSFP kanye ne-QSFP-DD amele isixazululo sokuxhuma esilandelayo esine-bandwidth ephezulu samadatha-centers amakhulu, ama-GPU clusters we-AI, ukubala okusezingeni eliphezulu (HPC), ingqalasizinda yamafu, kanye nezinhlelo zenethiwekhi ze-InfiniBand NDR/XDR. Ngokuhambisana ngokuphelele namazinga e-IEEE 802.3ck, OSFP MSA, QSFP-DD MSA kanye ne-CMIS 5.0, la ma-module optical we-800G ahlinzeka nge-bandwidth ephelele engu-800Gbps nge-8×106.25Gbps PAM4 lanes, asekelayo i-800G Ethernet, i-breakout 2×400G, 4×200G kanye ne-8×100G ukudluliswa kwe-dual-port okuminyene kakhulu.
Ulayini wethu ogcwele uhlanganisa ukufinyelela okuphelele kokudluliswa kusuka ku-multi-mode eseduze kakhulu kuya ku-fiber eyodwa ende kakhulu, okuhlanganisa nezinhlobonhlobo ze-SR8, DR8, FR8, LR8, ER8 kanye ne-ZR8, kusekela izinketho zokuxhuma ezimbili ze-LC duplex kanye nezimbili ze-MPO-12 APC. I-transceiver ngayinye engu-800G ihlanganisa i-integrated heat sink (IHS) eyenziwe kahle noma i-flat top heat sink yokuphatha ukushisa, i-DDM/DOM digital diagnostic monitoring eyakhelwe ngaphakathi, kanye nokusebenza okungenamaphutha nokuhambisana nemojuli ezikhona ezingama-400G. Lezi zinketho ezixhunywako zihambisana kahle ne-51.2T network switching fabrics, i-DGX H100 GPU servers, i-Spectrum-XGS switches, i-Arista/Cisco/Juniper enterprise & cloud routing platforms, ziqeda izithiyo ze-bandwidth ukuqeqeshwa okukhulu kwe-AI, ukucubungula idatha enkulu kanye nemisebenzi ye-HPC enokubambezeleka okuphansi.
Izinzuzo Zomkhiqizo Oyinhloko
1. I-Portfolio Ephelele Yokufinyelela, Ukumbozwa Kwesikhungo Sedatha Kusukela Ekuqaleni Kuze Kube Sekugcineni
Uchungechunge oluphelele lwebanga elifushane/eliphakathi/elide/elide kakhulu: 50m multi-mode SR8, 500m parallel single-mode DR8, 2km FR8, 10km LR8, 40km ER8, 120km ZR8, okuhlanganisa izimo ze-top-of-rack, i-leaf-spine, phakathi kwezikhungo zedatha kanye nokudluliswa kwe-optical kwe-metro.
2. Ukuhambisana Nezinto Ezisetshenziswa Ezihlukahlukene
I-Plug-and-play iyahambisana nama-NVIDIA/Mellanox Spectrum switches, ama-DGX H100 GPU systems, i-Arista, i-Cisco, i-Juniper, ama-generic whitebox switches, isekela i-InfiniBand NDR/XDR kanye ne-standard 800G Ethernet esetshenziswa kabili.
3. Idizayini Ethuthukisiwe Yokushisa Ne-Optical
Izinketho ezimbili zokufudumala: i-IHS enezimbambo ezikhethekile zezikhala ezijwayelekile, i-heat sink ephansi eyisicaba yamachassis amancane e-DGX H100; izinhlamvu ze-VCSEL/EML zekilasi lezimboni + ukucubungula isignali ye-Broadcom DSP, ukudluliswa kwesignali ye-PAM4 okuzinzile ngezinga eliphansi lamaphutha e-bit.
4.Ukuxilongwa Kwamadijithali Okujwayelekile Nokuhambisana
Ukuqapha okungokoqobo okwakhelwe ngaphakathi kwe-DDM/DOM kwezinga lokushisa, ugesi, amandla optical okudlulisa/okwamukelayo; ngokuphelele i-RoHS, i-IEEE 802.3ck, i-OSFP/QSFP-DD MSA, i-CMIS 5.0 eqinisekisiwe, ukusetshenziswa kwamandla okuphansi (12–16W evamile).
5.Ukuguquguquka Kwezimbili Zokuhlukanisa
Ikhono lokuhlukana elingu-2×400G, ukusebenza okungenamihawu namadivayisi enethiwekhi angu-400G asekhona, kunciphisa izindleko zokuthuthukisa ihadiwe kubasebenzisi bef<bos>udi kanye nezikhungo zedatha ezihlanganyelwe.
Ukwakheka Komugqa Wezinga Lemboni Ejwayelekile
1. Uchungechunge lwe-OSFP 800G (Octal Small Form-Factor Pluggable)
- I-Multi-Mode Short Reach (850nm VCSEL, Isixhumi se-MPO-12)
I-OSFP-800G-SR8: 850nm, 50m OM4/OM5 i-multi-mode fiber, i-duplex MPO-12, i-PAM4, i-DDM
I-OSFP-800G-SR8-100M: 850nm, 100m i-OM5 multi-mode fiber, i-MPO-12 ephindwe kabili, i-PAM4, i-DDM
- I-Parallel Single-Mode Medium Reach (1310nm, Isixhumi se-MPO-12)
OSFP-800G-DR8: 1310nm, 500m G.652 single-mode fiber, i-duplex MPO-12 APC, PAM4, DDM
OSFP-800G-DR8-FLT: Uhlaliswa wokushisa ophahleni oluyisicaba oluhlukile lwekhabhinethi encane ye-DGX H100, 500m
- CWDM Single-Mode Ephakathi Kuye Kude (1271/1291/1311/1331nm, Duplex LC)
OSFP-800G-FR8: CWDM 4-lambda, 2km G.652 SMF, i-duplex LC/UPC, PAM4, DDM
OSFP-800G-LR8: CWDM 4-lambda, 10km G.652 SMF, i-duplex LC/UPC, PAM4, DDM
- I-Ultra-Long Reach Single-Mode (Izinguquko Zokuhamba Okude ze-1310/1550nm)
I-OSFP-800G-ER8: 1310nm i-EML, 40km i-G.652 SMF, i-LC ephindwe kabili, i-PAM4, i-DDM
I-OSFP-800G-ZR8: 1550nm EML, 120km G.652 SMF, i-duplex LC, i-PAM4, i-DDM
2. Uchungechunge lwe-QSFP-DD 800G (Quad Small Form-Factor Pluggable Double Density)
- Multi-Mode Short Reach
I-QSFP-DD-800G-SR8: 850nm, 50m i-OM4/OM5, i-MPO-12 ephindwe kabili, i-PAM4, i-DDM
I-QSFP-DD-800G-SR8-100M: 850nm, 100m OM5, i-duplex MPO-12, i-PAM4, i-DDM
- I-Parallel Single-Mode
QSFP-DD-800G-DR8: 1310nm, 500m SMF, MPO-12 APC kabili, PAM4, DDM
- CWDM Long Reach
I-QSFP-DD-800G-FR8: 2km SMF, i-LC ephindwe kabili, i-PAM4, i-DDM
QSFP-DD-800G-LR8: 10km SMF, LC kabili, PAM4, DDM
QSFP-DD-800G-ER8: 40km SMF, i-LC ephindwe kabili, i-PAM4, i-DDM
QSFP-DD-800G-ZR8: 120km SMF, i-duplex LC, PAM4, DDM
Izimo Zokusebenzisa Eziyinhloko
1.Hyperscale AI & GPU Data Center
Ukuxhumana kwe-DGX H100/H200 GPU cluster, izixuku ezinkulu zokuqeqesha i-LLM, ukuhlanganiswa kwe-GPU okubambezelekile kancane, i-top-of-rack & i-leaf-spine 51.2T switch fabric uplink.
2.I-Cloud & Colocation Data Center
Ukushintsha okuyinhloko kwe-800G Ethernet, ukwehla kwe-2×400G breakout, ukudluliswa kwedatha esheshayo phakathi kwamaraki, ukuqoqwa kwenethiwekhi yokugcina yamafu.
3.High Performance Computing (HPC) & InfiniBand
I-InfiniBand NDR/XDR high-speed computing fabric, ukuxhumana kwe-supercomputer, izixhumanisi ze-optical zamakholomu wokubala ahambisanayo.
4.Amanye amanethiwekhi e-Enterprise & Carrier Metro
Ukuxhumana kwesikhungo sedatha (DCI), ukuxhumana okuyinhloko kwamabhizinisi, ukudluliswa kwe-optical kwe-metro yenkampani yenethiwekhi, inethiwekhi yasekampus yebanga eliphakathi neside.
Izincazelo Ezibalulekile Zobuchwepheshe
| Ipharamitha | Icaciso Ejwayelekile |
|---|---|
| I-Bandwidth Ephelele | 800Gbps (8×106.25Gbps PAM4) |
| Ifomethi Yokuhlanganisa | PAM4, 53.125GBaud |
| Electrical Interface | 800GAUI-8 / 2×400GAUI-4 |
| Izinga Lokuhambisana | IEEE 802.3ck, OSFP/QSFP-DD MSA, CMIS Rev 5.0 |
| Umsebenzi Wokuqapha | I-DDM/DOM Digital Diagnostic Monitoring |
| Izinga lokushisa lokusebenza | Ezokuhweba 0℃ ~ +70℃ |
| Ukusebenzisa Amandla | 12W ~ 16W (Ejwayelekile) |
| Ukuhambisana kwe-Fiber | OM4/OM5 Multi-mode, G.652D/G.657A Single-mode |
| Uhlobo Lwesixhumi | Dual Duplex LC UPC, Dual MPO-12 APC |
| Inketho ye-Heat Sink | I-Integrated Finned Heat Sink / I-Flat Top Low-Profile Heat Sink |
| Ukuhambisana | I-NVIDIA, i-Cisco, i-Arista, i-Juniper, ama-Whitebox Switches, ama-DGX H100 Servers |
Isigaba Sokuguqula Esingezansi
Ufuna ama-transceiver we-800G OSFP / QSFP-DD anezindleko eziphansi esikhungweni sakho sedatha ye-AI noma isixuku sakho se-HPC? Sihlinzeka ngama-module optical agcwele ahambisana nezinkundla ezijwayelekile zeswishi ne-GPU, anesitoko esizinzile, ukulebula okwenziwe ngendlela oyifisayo nokusekelwa kwama-oda amaningi. Thinta ithimba lethu lokuthengisa ukuze uthole amashidi edatha, ukuhlolwa kwesampula kanye namanani omthamo wama-transceiver we-800G SR8, DR8, FR8, LR8, ER8 kanye ne-ZR8 optical.